R-XPTIII-HD Hot Dip Galvanized Throughbolt

Hot Dip Galvanized throughbolt for non-cracked concrete

Features and benefits

  • Increased corrosion resistance due to hot dip zinc protection layer with a thickness of 50 µm
  • Design of R-XPTIII allows drilling and installing directly through the fixture and helps to reduce installation time
  • High quality with cost effectiveness
  • Cold formed body ensures consistent dimensional accuracy
  • Approved for outdoor use according to EAD EAD 330232-01-0601-01

Product information

Size

Product Code

Anchor

Fixture

Diameter

Length

Max. thickness tfix for:

Hole diameter

d

L

hnom,red

hnom,std

df

[mm]

[mm]

[mm]

[mm]

[mm]

M8

R-XPTIIIHD08060/10

8

60

-

10

9

R-XPTIIIHD08065/1

8

65

-

1

9

R-XPTIIIHD08075/10

8

75

-

10

9

R-XPTIIIHD08080/15

8

80

-

15

9

R-XPTIIIHD08095/30

8

95

-

30

9

R-XPTIIIHD08110/45

8

110

-

45

9

R-XPTIIIHD08115/50

8

115

-

50

9

R-XPTIIIHD08140/75

8

140

-

75

9

M10

R-XPTIIIHD10080/10

10

80

-

10

12

R-XPTIIIHD10095/25

10

95

-

25

12

R-XPTIIIHD10115/45

10

115

-

45

12

R-XPTIIIHD10130/60

10

130

-

60

12

R-XPTIIIHD10140/70

10

140

-

70

12

M12

R-XPTIIIHD12080/5

12

80

-

5

14

R-XPTIIIHD12100/5

12

100

-

5

14

R-XPTIIIHD12120/25

12

120

-

25

14

R-XPTIIIHD12125/30

12

125

-

30

14

R-XPTIIIHD12135/40

12

135

-

40

14

R-XPTIIIHD12150/55

12

150

-

55

14

R-XPTIIIHD12180/85

12

180

-

85

14

R-XPTIIIHD12220125

12

220

-

125

14

M16

R-XPTIIIHD16125/5

16

125

-

5

18

R-XPTIIIHD16140/20

16

140

-

20

18

R-XPTIIIHD16150/30

16

150

-

30

18

R-XPTIIIHD16180/60

16

180

-

60

18

R-XPTIIIHD16220100

16

220

-

100

18

Base material

  • Non-cracked concrete C20/25-C50/60

    Non-cracked concrete C20/25-C50/60

  • Unreinforced concrete

    Unreinforced concrete

  • Reinforced concrete

    Reinforced concrete

For use also with

  • Natural Stone (after site testing)

    Natural Stone (after site testing)

Applications

  • Cladding restraint
  • Curtain wall
  • Balustrading
  • Barriers
  • Handrails
  • Racking
  • Structural steel
  • Bollards

Installation guide

Installation guide
Installation guide
Installation guide
Installation guide
Installation guide
  1. Drill a hole of required diameter and depth
  2. Clear the hole of drilling dust and debris (using blowpump or equivalent method)
  3. Lightly tap the throughbolt through the fixture into hole with a hammer, until fixing depth is reached
  4. Tighten to the recommended torque

Installation data

Size

M8

M10

M12

M16

Thread diameter

d

[mm]

8

10

12

16

Hole diameter in substrate

d0

[mm]

8

10

12

16

Installation torque

Tinst

[Nm]

15

30

50

100

Wrench size

Sw

[mm]

13

17

19

24

STANDARD EMBEDMENT DEPTH

Min. hole depth in substrate

h0,s

[mm]

65

70

90

110

Min. installation depth

hnom,s

[mm]

55

60

80

100

Min. substrate thickness

hmin,s

[mm]

100

100

140

170

Min. spacing

smin, s

[mm]

50

70

75

95

Min. edge distance

cmin, s

[mm]

40

60

65

85

Associated products

  • RT-MAXA Drill bits Aggressor SDS max

    RT-MAXA Drill bits Aggressor SDS max

  • RT-SDSA Drill bits Aggressor SDS plus

    RT-SDSA Drill bits Aggressor SDS plus

  • RT-IS Long impact sockets 1/2

    RT-IS Long impact sockets 1/2"

  • RT-SDSR Drill bits Rebardrill SDS plus

    RT-SDSR Drill bits Rebardrill SDS plus

  • R-BLOWPUMP Blow Pump

    R-BLOWPUMP Blow Pump