R-LX-H-ZP Zinc Plated Hex Concrete Screw Anchor

Self-tapping concrete screwbolt

Features and benefits

  • Time-efficient installation through streamlined procedure - simply drill and drive
  • Completely removable with possibility of reuse
  • Unique design with patented threadform ensures high performance for relatively small hole diameter
  • Non-expansion functioning ensures low risk of damage to base material and makes R-LX ideal for installation near edges and adjacent anchors
  • High performance in both uncracked and cracked concrete
  • Different head types for any application
  • Oversize head for fixtures with elongated holes
  • Excellent product for temporary fixing
  • Suitable for standard and reduced embedment depth

Product information

Size

Product Code

Anchor

Fixture

Diameter

Length

Max. thickness tfix for:

Hole diameter

d

L

hnom,red

hnom,std

df

[mm]

[mm]

[mm]

[mm]

[mm]

8

R-LX-08X060-H-ZP

10

60

10

-

12

R-LX-08X075-H-ZP

10

75

25

5

12

R-LX-08X090-H-ZP

10

90

40

20

12

R-LX-08X100-H-ZP

10

100

50

30

12

R-LX-08X130-H-ZP

10

130

80

60

12

R-LX-08X150-H-ZP

10

150

100

80

12

10

R-LX-10X065-H-ZP

12.5

65

10

-

14

R-LX-10X075-H-ZP

12.5

75

20

-

14

R-LX-10X085-H-ZP

12.5

85

30

-

14

R-LX-10X100-H-ZP

12.5

100

45

15

14

R-LX-10X120-H-ZP

12.5

120

65

35

14

R-LX-10X140-H-ZP

12.5

140

85

55

14

R-LX-10X160-H-ZP

12.5

160

105

75

14

14

R-LX-14X105-H-ZP

17

105

30

-

18

R-LX-14X135-H-ZP

17

135

60

15

18

For use also with

  • Concrete

    Concrete

  • Cracked concrete C20/25-C50/60

    Cracked concrete C20/25-C50/60

  • Non-cracked concrete C20/25-C50/60

    Non-cracked concrete C20/25-C50/60

  • Reinforced concrete

    Reinforced concrete

  • Unreinforced concrete

    Unreinforced concrete

  • Natural Stone (after site testing)

    Natural Stone (after site testing)

Applications

  • Through-fixing
  • Temporary anchorages
  • Formwork support systems
  • Balustrading & handrails
  • Fencing & gates manufacturing and installation
  • Racking systems
  • Public seating
  • Scaffolding

Installation guide

Installation guide
Installation guide
Installation guide
Installation guide
Installation guide
  1. Drill the hole with rotary hammer drilling machine. Drill to a required depth.
  2. Blow out dust at least 4 times with a hand pump.
  3. Possibility of unscrewing and re-screwing.
  4. Tighten to the recommended torque.
  5. After installation.

Installation data

Size

8

10

14

Thread diameter

d

[mm]

9.9

12.4

17.4

Hole diameter in substrate

d0

[mm]

8

10

14

Wrench size

Sw

[mm]

15

17

22

Max. installation torque

Tinst

[Nm]

40

-

-

Max. torque for impact screw driver

Timp,max

[Nm]

900

950

950

STANDARD EMBEDMENT DEPTH

Real hole depth in substrate

h0

[mm]

L + 10 - tfix

L + 10 - tfix

L + 10 - tfix

Min. installation depth

hnom,s

[mm]

70

85

120

Min. substrate thickness

hmin,s

[mm]

110

130

190

Min. spacing

smin, s

[mm]

50

60

100

Min. edge distance

cmin, s

[mm]

50

60

100

REDUCED EMBEDMENT DEPTH

Min. hole depth in substrate

h0,r

[mm]

60

65

85

Real hole depth in substrate

h0

[mm]

L + 10 - tfix

L + 10 - tfix

L + 10 - tfix

Min. installation depth

hnom,r

[mm]

50

55

75

Min. substrate thickness

hmin,r

[mm]

100

100

110

Min. spacing

smin,r

[mm]

50

60

100

Min. edge distance

cmin,r

[mm]

50

60

100

STANDARD EMBEDMENT DEPTH

Min. hole depth in substrate

h0,s

[mm]

-

95

130

Downloads

Need documents for other product? Visit our Technical Library.

go to library

Associated products

  • RT-MAXA Drill bits Aggressor SDS max

    RT-MAXA Drill bits Aggressor SDS max

  • RT-SDSA Drill bits Aggressor SDS plus

    RT-SDSA Drill bits Aggressor SDS plus

  • RT-IS Long impact sockets 1/2

    RT-IS Long impact sockets 1/2"

  • RT-SDSR Drill bits Rebardrill SDS plus

    RT-SDSR Drill bits Rebardrill SDS plus

  • R-BLOWPUMP Blow Pump

    R-BLOWPUMP Blow Pump