R-HPTII-A4 Stainless Steel Throughbolt

Stainless steel throughbolt anchor for cracked and non-cracked concrete

Features and benefits

  • Stainless steel anchor for the highest corrosion resistance
  • High performance in cracked and non-cracked concrete confirmed by ETA Option 1
  • Highest quality ensures maximum load capability
  • For applications requiring fire resistance up to 120 minutes
  • Suitable for reduced embedment to avoid contact with reinforcement
  • Embedment depth markings help to ensure precise installation of the anchor
  • Design of R-HPTII allows drilling and installing directly through the fixture and helps to reduce installation time
  • Suitable for installation in corrosive environments category C1, C2, C3,C4 and C5
  • Anchors can be used in earthquake risk zones - seismic category C1 and C2

Product information

Size

Product Code

Anchor

Fixture

Diameter

Length

Max. thickness tfix for:

Hole diameter

Max. thickness

d

L

hnom,red

hnom,std

df

tfix

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

M8

R-HPTIIA4-08060/10

8

60

10

-

9

-

R-HPTIIA4-08075/10

8

75

25

10

9

-

R-HPTIIA4-08085/20

8

85

35

20

9

-

R-HPTIIA4-08095/30

8

95

45

30

9

-

R-HPTIIA4-08105/40

8

105

55

40

9

-

R-HPTIIA4-08115/50

8

115

65

50

9

-

M10

R-HPTIIA4-10065/5

10

65

5

-

12

-

R-HPTIIA4-10080/20

10

80

20

-

12

-

R-HPTIIA4-10095/15

10

95

35

15

12

-

R-HPTIIA4-10115/35

10

115

55

35

12

-

R-HPTIIA4-10130/50

10

130

70

50

12

-

R-HPTIIA4-10140/60

10

140

80

60

12

-

M12

R-HPTIIA4-12080/5

12

80

5

-

14

-

R-HPTIIA4-12100/5

12

100

25

5

14

-

R-HPTIIA4-12115/20

12

115

40

20

14

-

R-HPTIIA4-12125/30

12

125

50

30

14

-

R-HPTIIA4-12150/55

12

150

75

55

14

-

R-HPTIIA4-12180/85

12

180

105

85

14

-

M16

R-HPTIIA4-16125/5

16

125

25

5

18

-

R-HPTIIA4-16140/20

16

140

40

20

18

-

R-HPTIIA4-16150/30

16

150

50

30

18

-

R-HPTIIA4-16180/60

16

180

80

60

18

-

M12

R-HPTIIIA412115/40

12

115

-

-

14

40

Base material

  • Cracked concrete C20/25-C50/60

    Cracked concrete C20/25-C50/60

  • Non-cracked concrete C20/25-C50/60

    Non-cracked concrete C20/25-C50/60

  • Reinforced concrete

    Reinforced concrete

  • Unreinforced concrete

    Unreinforced concrete

For use also with

  • Natural Stone (after site testing)

    Natural Stone (after site testing)

Applications

  • Cladding restraints
  • Barriers
  • Structural steel
  • Curtain walling
  • Handrails
  • Heavy Plant
  • Balustrading
  • Passenger lifts
  • Facades
  • Fencing & gates manufacturing and installation
  • Masonry support
  • Platforms
  • Public seating
  • Racking systems

Installation guide

Installation guide
Installation guide
Installation guide
Installation guide
Installation guide
  1. Drill a hole of required diameter and depth
  2. Clear the hole of drilling dust and debris (using blowpump or equivalent method)
  3. Lightly tap the throughbolt through the fixture into hole with a hammer, until fixing depth is reached
  4. Tighten to the recommended torque

Installation data

Size

M8

M10

M12

M16

Thread diameter

d

[mm]

8

10

12

16

Hole diameter in substrate

d0

[mm]

8

10

12

16

Installation torque

Tinst

[Nm]

15

30

50

100

Wrench size

Sw

[mm]

13

17

19

24

External diameter of washer

[mm]

16

20

24

30

STANDARD EMBEDMENT DEPTH

Min. hole depth in substrate

h0,s

[mm]

65

80

90

110

Min. installation depth

hnom,s

[mm]

55

69

80

100

Min. substrate thickness

hmin,s

[mm]

100

120

140

170

Min. spacing (Non-cracked concrete)

smin, s

[mm]

55

70

90

135

Min. spacing (Cracked concrete)

smin, s

[mm]

55

70

90

135

Min. edge distance (Non-cracked concrete)

cmin, s

[mm]

40

50

55

80

Min. edge distance (Cracked concrete)

cmin, s

[mm]

40

45

55

70

REDUCED EMBEDMENT DEPTH

Min. hole depth in substrate

h0,r

[mm]

50

60

70

90

Min. installation depth

hnom,r

[mm]

40

49

60

80

Min. substrate thickness

hmin,r

[mm]

100

100

100

130

Min. spacing (Non-cracked concrete)

smin,r

[mm]

50

70

120

150

Min. spacing (Cracked concrete)

smin,r

[mm]

50

70

120

150

Min. edge distance (Non-cracked concrete)

cmin,r

[mm]

50

60

70

90

Min. edge distance (Cracked concrete)

cmin,r

[mm]

40

50

70

85

Min. edge distance

cmin

[mm]

-

-

55

-

Min. spacing

smin

[mm]

-

-

50

-

Associated products

  • RT-MAXA Drill bits Aggressor SDS max

    RT-MAXA Drill bits Aggressor SDS max

  • RT-SDSA Drill bits Aggressor SDS plus

    RT-SDSA Drill bits Aggressor SDS plus

  • RT-IS Long impact sockets 1/2

    RT-IS Long impact sockets 1/2"

  • RT-SDSR Drill bits Rebardrill SDS plus

    RT-SDSR Drill bits Rebardrill SDS plus

  • R-BLOWPUMP Blow Pump

    R-BLOWPUMP Blow Pump