GS Ceiling wedge anchor
Ceiling wire hanger for lightweight ceilings and suspended ceilings to solid building materials
Features and benefits
- During installation, when the nail is flush with the head, it signifies the complete expansion of the anchor
 - Steel body and pin ensure positive expansion and high safety in use
 - Approved for installation in cracked and non-cracket concrete.
 - Fire resistance class A1
 - Reliable setting thanks to the simple visual check
 - Impact expansion by hammer, no setting tool is needed
 
Product information
Size  | 
Product Code  | 
Anchor  | 
Fixture  | 
||
Diameter  | 
Length  | 
Max. thickness  | 
Hole diameter  | 
||
d  | 
L  | 
tfix  | 
df  | 
||
[mm]  | 
[mm]  | 
[mm]  | 
[mm]  | 
||
Ø6  | 
GS-06040  | 
5.8  | 
36  | 
4.5  | 
7  | 
GS-06065  | 
5.8  | 
65  | 
35  | 
7  | 
|
Base material
- 
														                                                            
														                                                        Cracked concrete C20/25-C50/60
 - 
														                                                            
														                                                        Non-cracked concrete C20/25-C50/60
 
Applications
- Installation of lightweight ceilings and suspended ceilings
 - Installation of coffered ceilings
 - Installation of conduit and pipe clamps and other MEP applications
 - Ventilation systems
 - Metal roof profiles
 - Punched straps
 
Installation guide
																	                                                                
																	                                                                
																	                                                                
																	                                                                - Drill a hole of required diameter and depth
 - Insert anchor through fixture into hole until fixing depth is reached.
 - Hammer-in the nail until flush with head.
 - Do not hit the expansion wedge at the stage.
 
Installation data
Size  | 
Ø6  | 
||
Hole diameter in substrate  | 
d0  | 
[mm]  | 
6  | 
Min. hole depth in substrate  | 
h0  | 
[mm]  | 
40  | 
Min. installation depth  | 
hnom  | 
[mm]  | 
32  | 
Min. substrate thickness  | 
hmin  | 
[mm]  | 
100  | 
Min. spacing  | 
smin  | 
[mm]  | 
200  | 
Min. edge distance  | 
cmin  | 
[mm]  | 
150  | 
Fixing diameter  | 
d  | 
[mm]  | 
5.8  |